Dimensions

GF Harvel EnviroKing®UV piping is available in two iron pipe size (IPS) pipe dimensions; ThinWall™ dimensions specifically developed for use in photobioreactor construction, and standard Schedule 40 dimensions, which provides sufficient wall thickness for many pressure applications.

ThinWall™
Dimensions and Pressure Ratings
Nom. Pipe
Size (inches)
O.D. Average
I.D.
Min.
Wall
Nominal
Wt./Ft.
Max. W.P.
PSI*
2 2.375 2.173 0.091 0.456 80
3 3.500 3.210 0.135 0.966 80
4 4.500 4.134 0.173 1.569 80
6 6.625 6.251 0.172 2.391 70
8 8.625 8.251 0.172 3.134 53
10 10.750 10.376 0.172 3.923 43
12 12.750 12.376 0.172 4.666 36
*Pressure ratings shown are for water, non-shock@73°F
Schedule 40
Dimensions and Pressure Ratings
Nom. Pipe
Size (inches)
O.D. Average
I.D.
Min.
Wall
Nominal
Wt./Ft.
Max. W.P.
PSI*
½ 0.840 0.602 0.109 0.170 300
¾ 1.050 0.804 0.113 0.226 240
1 1.315 1.029 0.133 0.333 220
1.660 1.360 0.140 0.450 180
1.900 1.590 0.145 0.537 170
2 2.375 2.047 0.154 0.720 140
2.875 2.445 0.203 1.136 150
3 3.500 3.042 0.216 1.488 130
4.000 3.521 0.226 1.789 120
4 4.500 3.998 0.237 2.118 110
6 6.625 6.031 0.280 3.733 90
*Pressure ratings shown are for water, non-shock@73°F